LIEBHERR LKPv 6523 Premium Medical / Laboratory Fridge – 617 litres – Glass Door

$10,670.00

LIEBHERR LKPv 6523 Premium Medical / Laboratory Fridge – 617 litres – Glass Door

Features of the LKPv 6523

  • 597 litres
  • Glass door
  • Fan forced
  • Made in Austria
  • Castors
  • Ventilated cooling system
  • Automatic defrost
  • Door lock
  • Self-closing door
  • 4 Adjustable shelves

Profi Controller

The Liebherr LKPv 6523 includes a menu-guided Profi electronic controller with integrated real-time clock allows the temperature to be set to 1/10°C accuracy. The text display has German, English, French, Spanish or Italian language setting options. To satisfy laboratory hygiene requirements, the electronic controller is flush-fitted and has an easy-clean membrane keypad.

Integrated alarm systems

A visual and audible temperature alarm alerts the user if temperature deviation limits are exceeded. Visual and audible door alarms are raised if the door is open for longer than 1 minute. There is also an immediate visual and audible alarm in the event of power failure.

Integrated data memory

The Profi electronic controller has an integrated data memory which logs the last 30 alarm events including date, time and maximum temperature as well as the internal temperature profile at 4-minute intervals. 2800 temperature logs are stored to memory, which corresponds to approximately a 7-day logging period.

3-point calibration

The laboratory appliances with Profi electronic controllers provide 3-point calibration for extremely accurate temperature control. This permits compensation between the set temperature and the actual internal temperature at as many as three temperature points. Positive or negative changes to the correction value can be made in steps of 0.1K.

The mains-independent power supply of the electronic controller

In case of power failure, the electronic controller continues to operate from an integrated 12 V battery. As a result, the memory continues to log the internal temperatures for another 72 hours even in the event of power failure. Furthermore, if external alarm and documentation systems are connected, the data transfer is maintained for as long as 72 hours.

Temperature settable range: 0°C to +16°C

LIEBHERR

LIEBHERR LKPv 6523 Premium Medical / Laboratory Fridge – 617 litres – Glass Door

Features of the LKPv 6523

  • 597 litres
  • Glass door
  • Fan forced
  • Made in Austria
  • Castors
  • Ventilated cooling system
  • Automatic defrost
  • Door lock
  • Self-closing door
  • 4 Adjustable shelves

Profi Controller

The Liebherr LKPv 6523 includes a menu-guided Profi electronic controller with integrated real-time clock allows the temperature to be set to 1/10°C accuracy. The text display has German, English, French, Spanish or Italian language setting options. To satisfy laboratory hygiene requirements, the electronic controller is flush-fitted and has an easy-clean membrane keypad.

Integrated alarm systems

A visual and audible temperature alarm alerts the user if temperature deviation limits are exceeded. Visual and audible door alarms are raised if the door is open for longer than 1 minute. There is also an immediate visual and audible alarm in the event of power failure.

Integrated data memory

The Profi electronic controller has an integrated data memory which logs the last 30 alarm events including date, time and maximum temperature as well as the internal temperature profile at 4-minute intervals. 2800 temperature logs are stored to memory, which corresponds to approximately a 7-day logging period.

3-point calibration

The laboratory appliances with Profi electronic controllers provide 3-point calibration for extremely accurate temperature control. This permits compensation between the set temperature and the actual internal temperature at as many as three temperature points. Positive or negative changes to the correction value can be made in steps of 0.1K.

The mains-independent power supply of the electronic controller

In case of power failure, the electronic controller continues to operate from an integrated 12 V battery. As a result, the memory continues to log the internal temperatures for another 72 hours even in the event of power failure. Furthermore, if external alarm and documentation systems are connected, the data transfer is maintained for as long as 72 hours.

Temperature settable range: 0°C to +16°C

LIEBHERR
General
Product Type
Cabinet Style
Certification
Noise [dBA]
Climate Rating
Warranty [years]
Doors
Number of doors
Door Material
Door Lock
Door Hinge
Reversible Door
Dimensions
Volume [litres]
Width / Depth / Height [mm]
Gross/Net Weight [kg]
Shelves
Number of shelves
Shelf material
Construction
Cabinet Finish
Interior Material
Castors
Spark Free Interior
Lighting
Controller functions
Controller type
Temperature Alarm
Door open alarm
Power Failure Alarm
Battery back-up for controller
Volt-free contact for alarm forwarding
RS 485 serial port for BMS connectivity
Includes data logger
Access port for external temp. probe
Temperature settings
Default set temperature
Default temperature range
Set point range
Refrigeration
Climate Rating
Cooling Type
Defrost Type
Refrigerant
Power
Power Connection
Power Consumption [kWh/year]

Brand