LIEBHERR LKv 3910 Vaccine Fridge – 361 litres – Solid Door

$4,675.00

LIEBHERR LKv 3910 Vaccine Fridge – 361 litres – Solid Door

LIEBHERR LKv 3910 Vaccine Fridge – 361 litres – Solid Door

LIEBHERR LKv 3910 Vaccine Refrigerator – 361 litres – Solid Door

The LIEBHERR LKv 3910 Vaccine refrigferator is designed and manufactured in AUSTRIA to the highest standards, is QCPP approved, and is ideal for use in pharmacies, doctors surgeries, hospitals and laboratories.

Key Features:

  • Quality Care Pharmacy Program (QCPP) approved
  • Capacity 386 litres
  • ENERGY EFFICIENT only 1.315 kWh / 24 hrs
  • Integrated alarms and data memory
  • External temperature and alarm documentation
  • ISO 60068-3 ensures optimal temperature stability & consistency
  • HACCP compliant electronic controller
  • 24 Months Warranty

Other Features:

  • Solid door
  • Dynamic refrigeration system
  • Automatic defrost
  • Door lock
  • Self-closing door
  • 9 adjustable storage shelves
  • Evaporator cover ensures that cold-sensitive products can’t touch the evaporator

Mediline vaccine refrigerators with Comfort electronic controllers are the ideal refrigeration solution for your vaccine. These appliances meet the exacting demands made of medical appliances. The temperature can be set from +3°C to +8°C. The forced-air cooling system in conjunction with the precision electronic controller ensures temperature consistency and uniform temperature distribution in the interior.

Comfort Controller

The precision Comfort electronic controller with digital temperature display enables temperatures to be set to 1/10°C accuracy. Symbols indicate the operating status of the appliance at all times. To satisfy medical hygiene requirements, the Comfort electronic controller is flush-mounted and has an easy clean membrane keypad.

Integrated alarm systems

A visual and audible temperature alarm alerts the user if temperature deviation limits are exceeded. The parameters for the temperature alarm can be individually set. In addition, a visual and audible door alarm is raised if the door is open for longer than 1 minute. Furthermore, the medical

Integrated data memory

The Comfort electronic controller has an integrated data memory. It logs the maximum and minimum internal temperatures that occurred once the set temperature was reached, the last three temperature alarms and power failures, together with the time, date and duration of the alarm. The respective data can be recalled using the AlarmLog function and read on the display panel.

1-point calibration

The medical appliances with Comfort electronic controllers provide 1-point calibration for accurate temperature control. This permits compensation between the set temperature and the actual internal temperature. Positive or negative changes to the correction value can be made in steps of 0.1K.

Maximum temperature stability and temperature consistency

In conjunction with the precision Comfort electronic controller, the forced-air cooling system of the vaccine refrigerators and the static cooling system of the medical freezers with spark-free interior ensure maximum temperature stability and high-temperature consistency. The vaccine refrigerators are equipped with a secondary safety thermostat to prevent temperatures below +2°C in case of a fault. All the medical appliances with Comfort electronic controllers are tested according to the NF X 15-140 standard with regard to maximum temperature stability and optimal temperature consistency.


LIEBHERR
General
Product Type
Cabinet Style
Certification
Noise [dBA]
Climate Rating
Warranty [years]
Doors
Number of doors
Door Material
Door Lock
Door Hinge
Reversible Door
Dimensions
Volume [litres]
Width / Depth / Height [mm]
Gross/Net Weight [kg]
Shelves
Number of shelves
Shelf material
Construction
Cabinet Finish
Interior Material
Castors
Spark Free Interior
Lighting
Controller functions
Controller type
Temperature Alarm
Door open alarm
Power Failure Alarm
Battery back-up for controller
Volt-free contact for alarm forwarding
RS 485 serial port for BMS connectivity
Includes data logger
Access port for external temp. probe
Temperature settings
Default set temperature
Default temperature range
Set point range
Refrigeration
Climate Rating
Cooling Type
Defrost Type
Refrigerant
Power
Power Connection
Power Consumption [kWh/year]

 